VNC1705E

xxxx is not a VNAC subsystem

The VNAC Command Prefix facility requires that the owner of the CPF string be a VNAC MVS subsystem, but the owner of the CPF string specified in the input parameter to the utility is not a VNAC subsystem.

Action: Edit the parm input to the utility to specify the correct CPF string and resubmit the job.

VNC1704E

The owner of the CPF string is not a subsystem

The VNAC Command Prefix facility requires that the owner of the CPF string be a VNAC MVS subsystem, but no subsystem with a matching name was found on this system.

Action: Edit the parm input to the utility to specify the correct CPF string and resubmit the job.

VNC1703I

CPF string string was deleted

While processing a DELETE command for a Command Prefix string, the utility found that the CPF string was not defined on the system that the job ran on.

Action: No action is required if the CPF string is correct and the job ran on the correct system. Otherwise, edit the parm input to the utility to specify the correct CPF string and resubmit the job.

VNC1702E

CPF string not defined on this system

While processing a DELETE command, the utility determined that the specified Command Prefix string is not defined on the system that the utility ran on, or it is defined but owned by another system.

Action: If the CPF string is owned by another system in the sysplex, run the job on that system to delete the CPF string.

VNC1701E

ADD command syntax error. Found operands after scope operand

The syntax for the ADD command for a CPF string is ADD,cpf string,target subsystem,scope but the utility found additional operands after the scope parameter.

Action: Edit the parm input to the utility to remove the additional operands and resubmit the job.

VNC1700E

Scope missing or invalid. Must be SYSTEM or SYSPLEX

The syntax for the ADD command for a CPF string is ADD,cpf string,target subsystem,scope but the utility found that the scope operand is missing or not one of those listed.

Action: Edit the parm input to the utility to include the required scope and resubmit the job.

VNC1612E

Option option is invalid

The option option entered after the subsystem name in the parm input to the utility is invalid.

Action: Correct or remove the option and rerun the job.

VNC1611E

Release of VNCDSSSR at x′address′ length=x′length′failed. RC=X′return-code′

The STORAGE RELEASE macro for the storage holding the VNAC Subsystem Service routine in the ECSA at address address with length length failed with return code return-code.

Action: Review the return code for the STORAGE RELEASE macro for a possible resolution. Contact SDS Technical Support for additional assistance.

VNC1610E

Release of VNCDSSCA at x′address′ length=x′length′ failed. RC=X′return-code′

The STORAGE RELEASE macro for the VNAC Subsystem Control Area in the ECSA at address address with length length failed with return code return-code.

Action: Review the return code for the STORAGE RELEASE macro for a possible resolution. Contact SDS Technical Support for additional assistance.

VNC1609E

Subsystem token mismatch

After issuing a IEFSSI REQUEST=DEACTIVATE for the subsystem, the utility determined that the token for the subsystem entry that was returned by the request was not the same as that saved by the agent when the subsystem was initialized.

Action: This may be a storage overlay issue or another application has incorrectly used the subsystem in some way. Contact SDS Technical Support.