xxxx is not a VNAC subsystem
The VNAC Command Prefix facility requires that the owner of the CPF string be a VNAC MVS subsystem, but the owner of the CPF string specified in the input parameter to the utility is not a VNAC subsystem.
Action: Edit the parm input to the utility to specify the correct CPF string and resubmit the job.
The owner of the CPF string is not a subsystem
The VNAC Command Prefix facility requires that the owner of the CPF string be a VNAC MVS subsystem, but no subsystem with a matching name was found on this system.
Action: Edit the parm input to the utility to specify the correct CPF string and resubmit the job.
CPF string string was deleted
While processing a DELETE command for a Command Prefix string, the utility found that the CPF string was not defined on the system that the job ran on.
Action: No action is required if the CPF string is correct and the job ran on the correct system. Otherwise, edit the parm input to the utility to specify the correct CPF string and resubmit the job.
CPF string not defined on this system
While processing a DELETE command, the utility determined that the specified Command Prefix string is not defined on the system that the utility ran on, or it is defined but owned by another system.
Action: If the CPF string is owned by another system in the sysplex, run the job on that system to delete the CPF string.
ADD command syntax error. Found operands after scope operand
The syntax for the ADD command for a CPF string is ADD,cpf string,target subsystem,scope but the utility found additional operands after the scope parameter.
Action: Edit the parm input to the utility to remove the additional operands and resubmit the job.
Scope missing or invalid. Must be SYSTEM or SYSPLEX
The syntax for the ADD command for a CPF string is ADD,cpf string,target subsystem,scope but the utility found that the scope operand is missing or not one of those listed.
Action: Edit the parm input to the utility to include the required scope and resubmit the job.
Option option is invalid
The option option entered after the subsystem name in the parm input to the utility is invalid.
Action: Correct or remove the option and rerun the job.
Release of VNCDSSSR at x′address′ length=x′length′failed. RC=X′return-code′
The STORAGE RELEASE macro for the storage holding the VNAC Subsystem Service routine in the ECSA at address address with length length failed with return code return-code.
Action: Review the return code for the STORAGE RELEASE macro for a possible resolution. Contact SDS Technical Support for additional assistance.
Release of VNCDSSCA at x′address′ length=x′length′ failed. RC=X′return-code′
The STORAGE RELEASE macro for the VNAC Subsystem Control Area in the ECSA at address address with length length failed with return code return-code.
Action: Review the return code for the STORAGE RELEASE macro for a possible resolution. Contact SDS Technical Support for additional assistance.
Subsystem token mismatch
After issuing a IEFSSI REQUEST=DEACTIVATE for the subsystem, the utility determined that the token for the subsystem entry that was returned by the request was not the same as that saved by the agent when the subsystem was initialized.
Action: This may be a storage overlay issue or another application has incorrectly used the subsystem in some way. Contact SDS Technical Support.