VNC0815D

SCIREQ RECV completed with retc=return-code (text), rsnc=reason-code (text); data=data-adr; dlen=data-len; msgi=msg-id

This diagnostic message records the System Logger’s attempt to receive a message from the system console intercept.

VNC0814D

SCIREQ LSTN completed with retc=return-code (text), rsnc=reason-code (text)

This diagnostic message records the System Logger’s attempt to open a connection to receive messages from the system console intercept.

VNC0813E

Failed to open the system console listener, retc=return-code (text), rsnc=reason-code (text)

The System Logger was unable to open a connection to receive messages from the system console. This will prevent logging of certain messages.

Action: Restart the agent. If the condition persists, contact SDS Technical Support.

VNC0811E

Failed to remove system console listener listener-name, retc=return-code, rsnc=reason-code

A system console listener could not be removed. This message can be issued one or more times during processing of an OBEYFILE command.

Action: Look for other messages providing more information about the error. If the condition persists, contact SDS Technical Support.

VNC0807W

Message log rate has reached nnn percent of MaxLogRate threshold of mmm logged messages per minute

nnn is the warning threshold percentage for the MaxLogRate parameter

mmm is the maximum number of logged messages within the current one-minute interval as specified by the MaxLogRate parameter

VNC0806W

Command rate has reached nnn percent of MaxCmdRate threshold of mmm commands per minute.

where:
nnn is the warning threshold percentage for the MaxCmdRate parameter
and mmm is the maximum number of commands within the current one-minute interval as specified by the MaxCmdRate parameter.

VNC0805W

nnn commands were suppressed by MessageRules MaxCmdRate configuration.

VNAC agents many invoke REXX excecs in response to system messages at a maximum rate of nnn commands per minute, where nnn is the MaxCmdRate specified in the agent configuration member.

Action: If too many commands are suppressed, adjust the value of MaxCmdRate.

VNC0804I

Message Filter Block installed at address.

A message filter control block has been installed at the address provided. This message can be issued at startup or during processing of an OBEYFILE command.

Action: None. This is an informational message.

VNC0803W

nnn messages were suppressed by MessageRules MaxLogRate configuration.

VNAC agents send system messages to the VNAC server and database at a maximum rate of xxx lines per minute, where nnn is the MaxLogRate specified in the agent configuration member.

Action: If too many messages are suppressed, adjust the value of MaxLogRate.

VNC0802I

Removed system console listener listener-name.

A system console listener has been removed. This message can be issued one or more times during processing of an OBEYFILE command.

Action: None. This is an informational message.