VNC0819D

RECV SCI alert message: RTC=return-code, RSN=reason-code, ADR=address, LEN=length, MID=message-id

This message is for diagnostics only.

VNC0818D

ADD|DELETE SCI alert listener filters: RTC=return-code, RSN=reason-code, failed|successful

This message is for diagnostics only.

VNC0817D

program-name: processing-step user user-name job job-name filter filter-name

Debug message issued by VNCVTL03, the send-to-user-list message processor. It shows the processing step in the program and identifies the filter that was the source of the user list being processed.

The value of processing-step is send to, active, or inactive.

The value of user-name is the user ID for the session window where the message will be sent. The ID comes from from the user list identified in the message filter.

The value of job-name is from the message filter that contained the user list.

The value of filter-name identifies the message filter that contained the user list.

VNC0816E

Message notification arrived with no SCIR

The System Logger was notified of a new system console message, but the notification did not include any data.

Action: If the condition persists, contact SDS Technical Support.

VNC0815D

SCIREQ RECV completed with retc=return-code (text), rsnc=reason-code (text); data=data-adr; dlen=data-len; msgi=msg-id

This diagnostic message records the System Logger’s attempt to receive a message from the system console intercept.

VNC0814D

SCIREQ LSTN completed with retc=return-code (text), rsnc=reason-code (text)

This diagnostic message records the System Logger’s attempt to open a connection to receive messages from the system console intercept.

VNC0813E

Failed to open the system console listener, retc=return-code (text), rsnc=reason-code (text)

The System Logger was unable to open a connection to receive messages from the system console. This will prevent logging of certain messages.

Action: Restart the agent. If the condition persists, contact SDS Technical Support.

VNC0811E

Failed to remove system console listener listener-name, retc=return-code, rsnc=reason-code

A system console listener could not be removed. This message can be issued one or more times during processing of an OBEYFILE command.

Action: Look for other messages providing more information about the error. If the condition persists, contact SDS Technical Support.

VNC0807W

Message log rate has reached nnn percent of MaxLogRate threshold of mmm logged messages per minute

nnn is the warning threshold percentage for the MaxLogRate parameter

mmm is the maximum number of logged messages within the current one-minute interval as specified by the MaxLogRate parameter

VNC0806W

Command rate has reached nnn percent of MaxCmdRate threshold of mmm commands per minute.

where:
nnn is the warning threshold percentage for the MaxCmdRate parameter
and mmm is the maximum number of commands within the current one-minute interval as specified by the MaxCmdRate parameter.