VNC1042I

SAWHELP (display SAW help information)

VNC1041I

SAWHELP: SAWDIAG (display historical diagnostic information)

VNC1040I

SAWHELP: Begin Session Awareness Monitor (SAW) help information

This is the first response message to the SAWHELP command.

VNC1039I

SAWDIAG: End Session Awareness Monitor diagnostic information

This is the final response message to the SAWDIAG command. Time stamps report the time of the error, except when messages VNC1031E, VNC1032E, VNC1033E are accompanied by messages VNC1030I and VNC1039I.

In those cases, previous errors are being displayed in response to a SAWDIAG command and the time stamps represent the time of the SAWDIAG command, not the time of the error(s).

Consecutive repeated VTAM errors of the same kind will be suppressed at the time of the error, but may be displayed by means of the SAWDIAG command.

VNC1038E

SAWDIAG: Following SAWDIAG correlates to //VNCSAW DIAGNOSED SawBuffer, SawEntry RRN rrn

This message provides a Relative Record Number (rrn) that may be used to correlate these SAWDIAG messages with a SawBuffer/SawEntry within the //VNCSAW print file.

VNC1033E

SAWDIAG: + RtnCode=return-code, RsnCode=reason-code, ErrCode=error-code, Occurrences=nn

This message details the error indicators provided by the failing function and specifies how many times this error occurred.

Time stamps report the time of the error, except when messages VNC1031E, VNC1032E, VNC1033E are accompanied by messages VNC1030I and VNC1039I.

In those cases, previous errors are being displayed in response to a SAWDIAG command and the time stamps represent the time of the SAWDIAG command, not the time of the error(s).

Consecutive repeated VTAM errors of the same kind will be suppressed at the time of the error, but may be displayed by means of the SAWDIAG command.

VNC1032E

SAWDIAG: + function. explanation

This message identifies the function that experienced the error and provides a human-readable explanation of the error.

Time stamps report the time of the error, except when messages VNC1031E, VNC1032E, VNC1033E are accompanied by messages VNC1030I and VNC1039I.

In those cases, previous errors are being displayed in response to a SAWDIAG command and the time stamps represent the time of the SAWDIAG command, not the time of the error(s).

Consecutive repeated VTAM errors of the same kind will be suppressed at the time of the error, but may be displayed by means of the SAWDIAG command.

VNC1031E

SAWDIAG: Error detected at program+offset

This message identifies the program that experienced the error, and the offset within the program where the error occurred. This information may be used to locate the place of the error within a compilation listing of the program.

Time stamps report the time of the error, except when messages VNC1031E, VNC1032E, VNC1033E are accompanied by messages VNC1030I and VNC1039I.

In those cases, previous errors are being displayed in response to a SAWDIAG command and the time stamps represent the time of the SAWDIAG command, not the time of the error(s).

Consecutive repeated VTAM errors of the same kind will be suppressed at the time of the error, but may be displayed by means of the SAWDIAG command.

VNC1030I

SAWDIAG: Begin Session Awareness Monitor diagnostic information

This is the first response message to the SAWDIAG command.

Time stamps report the time of the error, except when messages VNC1031E, VNC1032E, VNC1033E are accompanied by messages VNC1030I and VNC1039I.

In those cases, previous errors are being displayed in response to a SAWDIAG command and the time stamps represent the time of the SAWDIAG command, not the time of the error(s).

Consecutive repeated VTAM errors of the same kind will be suppressed at the time of the error, but may be displayed by means of the SAWDIAG command.

VNC1024E

SAWparse: Adr#1/Len#1 = address1/length1. Adr#2/Len#2 = address2/length2.

This message contains address/length information of sections within a snapdump that should be scrutinized to determine the exact nature of the parsing error.