VNC1245E

Subsystem xxxx is not a VNAC subsystem

Description: While preparing to connect to the subsystem xxxx, the agent detected that the subsystem named by the GlobalConfig startup parameter Subsystem, is not a VNAC subsystem.

Action: If connecting to an existing VNAC subsystem, change the VNAC agent GlobalConfig startup parameter, Subsystem, to specify the name of an existing VNAC subsystem.

VNC1244E

Version mismatch program version=program version control block version=cb version

Description: While preparing to connect to the subsystem, the agent detected a difference between the internal subsystem version program version assembled into program program and the control block version, cb version, in the control block.

Possible causes are that service has updated the program code, but the subsystem has not been cleared and reinitialized.

Action: Contact SDS Technical Support.

VNC1243I

Subsystem command processor is available using cpf

Description: The agent has connected to the VNAC subsystem and is using the command prefix string cpf.

Action: None.

VNC1242I

Command: verb operands

Description: The agent received the command indicated by verb operands.

Action: None.

VNC1241E

Error sending SWE to command task

Description: While processing a command from the subsystem, the agent was unable to send the SWE (SDS Common Interface Work Element) control block containing the command to the VNAC command processing task.

Action: Review the agent logs for additional messages that may indicate why the agent was unable to schedule the SWE to the command task. Contact SDS Technical Support.

VNC1240E

Error allocating SWE. Command not processed.

Description: While processing a command from the subsystem, the agent was unable to obtain an SWE (SDS Common Interface Work Element) control block. The command is not processed by the agent.

Action: Review the agent logs for additional messages that may indicate why the agent was unable to obtain the SWE. Contact SDS Technical Support.

VNC1239E

No response from agent agent

Description: The subsystem had passed a command to the agent agent and was waiting for an acknowledgement that the command had been received, but the wait timed out before the agent responded.

Action: The command may still be processed by the agent. Review the agent logs to determine if the command was processed or not.

VNC1238W

Error releasing ECSA UTOKEN storage

Description: After processing a command, the subsystem was attempting to release ECSA storage used to hold the user token for the command. The STORAGE RELEASE failed. The ECSA storage may be orphaned.

Action: If the problem persists, contact SDS Technical Support.

VNC1237E

Unable to obtain ECSA storage for user token. Cannot process command.

Description: The subsystem was attempting top obtain ECSA storage to hold the user token associated with a command but the STORAGE OBTAIN macro failed.

Action: Retry the command. If the problem persists, contact SDS Technical Support.

VNC1236E

No command text entered

Description: The subsystem detected a command prefixed by a command prefix string (CPF) belonging to an agent but no text was entered after the CPF string. The command is ignored.

Action: Reenter the Command Prefix string (CPF) with command text.