Timer error, unable to process command
Description: The subsystem attempting to create a timer while it passed a command to an agent, but the STIMERM SET macro failed. The command is not passed to the agent.
Action: Retry the command. Contact SDS Technical Support.
Agent agent is busy
Description: The subsystem was attempting to pass a command to agent, but the agent is busy processing another command.
Action: Reissue the command. If the problem persists, us a MODIFY command against the agent to issue the SSINO,D command to obtain a hex printout of the subsystem control blocks and then contact SDS Technical Support.
type RESMGR DELETE failed. RC=return-code
Description: The subsystem disconnect service subroutine was attempting to delete an Address Space (type=ADRSPACE) or Task (type=TASK) level resource manager. The RESMGR DELETE macro failed with return code return-code.
Action: Review the return code information for the RESMGR DELETE macro.
type RESMGR ADD failed. RC=return-code.
Description: The subsystem connection service subroutine was attempting to create an Address Space (type=ADRSPACE) or Task (type=TASK) level resource manager. The RESMGR ADD macro failed with return code return-code.
Action: Review the return code information for the RESMGR ADD macro.
FDA=fda data SSAA=ssaa data
Description: This message may be issued after message VNC1229E. It displays the contents of the FDA and SSAA fields indicated by message VNC1229E as hexadecimal data.
Action: Contact SDS Technical Support.
FDA=fda data SSAA=ssaa data
Description: This message may be issued after message VNC1229E. It displays the contents of the FDA and SSAA fields indicated by message VNC1229E as character data.
Action: Contact SDS Technical Support.
VNCSS251 Mismatch between fieldname in FDA and SSAA
Description: While disconnecting from a subsystem, the service routine determined that instance data in fieldname of the agent control block did not match that passed to it by the agent.
Action: See also message VNC1230E or VNC1231E. Contact SDS Technical Support.
Subsystem 251 index nnn is invalid
Description: While disconnecting from a subsystem, the service routine determined that the index, nnn, of the agent control block passed to it was invalid.
Action: Contact SDS Technical Support.
Subsystem Service routine address for function nnn is zero
Description: While reloading the subsystem service routine, the agent determined that there was no service subroutine for function nnn. This is a possibly a packaging error.
Action: Contact SDS Technical Support.
Release of VNCSSSR at address, length length for subsystem xxxx not released. RC=return-code.
Description: While reloading the subsystem service routine, the STORAGE RELEASE macro gave return code return-code. The agent was unable to release the old service routine at address with length length for subsystem xxxx.
Action: Review the return code information for the STORAGE RELEASE macro. Contact SDS Technical Support.