VNC1225E

VNCSSSR at address, length length for subsystem xxxx not released. # users = nnn.

Description: While reloading the subsystem service routine, the agent was unable to release the old service routine at address with length length for subsystem xxxx because the control block indicates that there are still nnn users (command issuers) still executing the old service routine code.

Action: Contact SDS Technical Support>.

VNC1224E

reply is invalid. Reply Go or CANCEL.

Description: The reply given to message VC1223E is incorrect.

Action: Reply GO or CANCEL. See message VNC1223E for a description of the required action.

VNC1223E

Unable to quiesce subsystem. Reply GO to override or CANCEL to quit.

Description: The agent is attempting to quiesce the subsystem in order to reload the service routine. However, after waiting thirty seconds, the number of command issuers using the subsystem is still not zero.

Action: Reply GO to the WTOR to override the check for any command issuer using the subsystem. This allows the agent to continue with the service routine reload. Be aware that any user using the existing service routine code in ECSA may subsequently fail or abend.

Reply CANCEL to cancel the service routine reload by the agent. The agent continues to initialize but the subsystem service routine is not reloaded. If service has affected the subsystem control block layouts, the subsystem and agent may ignore commands using the CPF string due to incompatible subsystem service level markers.

Contact SDS Technical Support.

VNC1222E

Unable to reload service routine for subsystem xxxx

Description: The agent encountered and error while reloading the VNAC subsystem service routine for subsystem xxxx.

Action: Review the agent logs for previous messages that indicate the cause of the failure.

VNC1221E

IEFSSI REQUEST=DEACTIVATE FOR SUBSYSTEM xxxx. RC=return-code REASON=reason-code.

Description: While reloading the VNAC subsystem service routine, the IEFSSI REQUEST=DEACTIVATE for subsystem xxxx failed with return code return-code and reason code reason-code.

Action: Review the return code information for the IEFSSI macro.

VNC1220E

Error disconnecting from subsystem xxxx, RC=return-code SSOB RC=ssobrc

Description: While disconnecting from subsystem xxxx the agent received return code return-code from the VNAC agent disconnect function and return code ssobrc from the subsystem interface.

Action: Contact SDS Technical Support.

VNC1219I

Agent has disconnected from subsystem xxxx

Description: The agent has successfully disconnected from subsystem xxxx.

Action: None.

VNC1218I

Agent has connected to subsystem xxxx

Description: The agent has successfully connected to subsystem xxxx.

Action: None.

VNC1217E

Error connecting to subsystem xxxx, RC=return-code SSOB RC=ssobrc

Description: While connecting to subsystem xxxx the agent received return code return-code from the VNAC agent connect function and return code ssobrc from the subsystem interface.

Action: Contact SDS Technical Support.

VNC1216E

CPF REQUEST=DEFINE,PREFIX=string,OWNER=owner,SCOPE=scope RC=return-code REASON=reason-code

Description: The CPF REQUEST=DEFINE request for prefix string with owner of owner and scope scope failed with return code return-code and reason reason-code.

Action: Review the return code and reason codes for the CPF macro.